Even if a building looks green on paper, it can waste thousands of dirhams every month because no one checks where the power goes. The Socomec Countis E50 is a three-phase energy meter that is mounted on a panel. It gives facility teams that kind of information without the high cost of a full power-quality analyzer.
This guide talks about the Socomec Countis E50’s dimensions, how it is set up and connected, and where it fits on sites in Dubai and the UAE. It also breaks down the E50 and E53 so you can pick the right one the first time.
What Is the Socomec Countis E50 Energy Meter?
The Socomec Countis E50 is an active and reactive energy meter that can be mounted on a panel and works with either single-phase or three-phase networks. According to Socomec’s own literature, it is a meter that displays energy and other values directly on a large, backlit LCD screen. It is intended for use in data centers, industries, and infrastructure.
It really is inside a switchboard and keeps track of how much power a feeder, machine, floor, or renter area uses. The Socomec Countis E50 is made to connect to a current transformer (CT), so it can handle feeders that are much bigger than a direct-connect meter can.
What the Socomec Countis E50 measures
According to Socomec’s catalogue, the meter records:
- Active energy (kWh), in both directions
- Reactive energy (kvarh)
- Apparent energy (kVAh)
- Instantaneous values such as voltage, current, power and power factor
The catalogue also notes two partial counters with reset. As a result, you can meter consumption over a defined period, such as a billing month or a production batch, without losing the totalising count.
Pulse output: what it means for you
The E50 is the form of the range that has a pulse output. Because each pulse has a set amount of energy, a PLC, building management system, or Socomec’s COUNTIS Ci concentrator can keep track of pulses and data on energy use. A pulse output, on the other hand, only sends energy counts. The Modbus model, which we’ll talk about later in this article, is what you need to send voltage, current, or power values to a BMS.
Socomec Countis E50 Technical Specifications
Before ordering, confirm each figure against the current Socomec datasheet for your exact reference. The values below come from Socomec’s published catalogue and distributor listings.
| Parameter | Socomec Countis E50 |
| Reference (3-phase, CT/5 A, pulse output) | 4850 3010 |
| Format | 96 × 96 mm panel mount |
| Panel cutout | 92 × 92 mm |
| Display | Large backlit LCD |
| Network | Three-phase or single-phase |
| CT connection | Configurable CT ratio, up to 6,000 A primary |
| Minimum current (Imin) | 50 mA |
| Reference current (Iref) | 5 A |
| Permanent overload (Imax) | 6 A |
| Standards | IEC 62053-21, IEC 62053-23, IEC 61557-12 |
| Output | Pulse |
Voltage and current range
A listing for a distributor says that the series can measure between 86 V and 520 V and 3 mA and 6 A. In other words, the meter can handle short overloads and a 5 A CT secondary. The catalog says it can handle 50 A for one second.
Accuracy: check before you specify
The 2010–2011 Socomec catalogue lists accuracy under IEC 62053-21 class 1 for active energy. Some distributor pages show different class wording. Therefore, always read the current datasheet for your reference if accuracy class matters for your tender or audit.
Setting the CT ratio
The user sets the CT ratio from the front keypad and display. For example, a 1,000/5 A CT means the meter multiplies its readings by 200. A wrong ratio is the most common reason for readings that are off by a clean multiple, so record it on the commissioning sheet.
Why Energy Metering Matters in Dubai and the UAE
Dubai has set performance goals that can be measured. Businesses can show that they are meeting these goals by using meters. From 2013 to 2030, the Dubai Supreme Council of Energy wants to cut the amount of water and energy used by 30%. This is called the Demand Side Management (DSM) Strategy. DEWA told MEED that Dubai changed its strategy in 2024 so that it aimed to save at least 30% by 2030 and 50% by 2050 compared to doing business as usual.
Here, commercial buildings are the most important. Energy & Utilities published an interview with a senior DSCE official who said that commercial buildings in Dubai use the most electricity. As a result, most of the opportunities are in places like offices, stores, hotels, and warehouses.
Sub-metering turns targets into numbers
A single utility bill hides which floor, chiller, lift group or production line drives the load. Sub-metering with a device like the Socomec Countis E50 breaks the total into feeders. Furthermore, once you can see each feeder, you can spot night-time baseload, chillers running outside schedule and underused equipment.
Reactive energy and power factor
Because the E50 also records reactive and apparent energy, it helps you see power-factor problems on motor-heavy or HVAC-heavy feeders. Poor power factor increases current for the same useful power, which stresses cables and transformers. Check your DEWA or utility tariff conditions to see how reactive demand is treated for your premises.
Where the Socomec Countis E50 Fits on UAE Sites
The E50 is a sub-metering and energy-monitoring tool. It is strongest where you want reliable energy counts per feeder at a sensible cost, and where a pulse signal is enough.
Commercial buildings and facilities management
In offices, malls and hotels, installers typically place meters on chiller plant, AHU and FCU distribution boards, lifts, lighting and tenant or department feeders. Consequently, facility managers can allocate cost internally and track month-on-month change after an efficiency project.
Industrial plants and data centres
Factories and data halls can meter production lines, compressors, UPS input and output, and PDU feeders. Socomec lists data centres among its target uses for the range. For UPS-backed loads, metering input and output shows how much energy the power chain itself consumes.
Where the E50 is not the right choice
People aren’t told that the E50 is a billing-grade (MID-certified) meter. If you have to officially bill your tenants, make sure you know the metering rules for your property and utility company before you choose a meter. In this case, Socomec’s different MID-certified Countis models might work better. Check with Socomec or your integrator to be sure.
Socomec Countis E50 vs E53 and Other Countis Meters
The most common question is whether to choose the E50 or the E53. The difference is the communication output.
| Feature | Countis E50 | Countis E53 |
| Reference (CT/5 A) | 4850 3010 | 4850 3011 |
| Output | Pulse | RS485 Modbus (JBUS/MODBUS) |
| Best for | Simple energy counting, PLC pulse inputs, concentrator connection | BMS/SCADA integration with richer data |
| Remote data | Energy counts via pulses | Energy and measured values over Modbus |
| Relative price (Europe, ex VAT, one distributor) | About €173 | About €208 |
Prices are from a single European distributor listing and are indicative only. UAE pricing, VAT and lead times will differ.
Choose the E50 when…
- Your BMS or PLC already has spare pulse inputs
- You only need kWh totals per feeder
- You want to keep cabling simple and the budget tight
Choose the E53 when…
- You want live voltage, current and power in your BMS or SCADA
- You plan to expand the monitoring system later
- You want to avoid pulse-weight configuration errors
Note that Socomec has also introduced newer ranges such as COUNTIS P. Before specifying the Socomec Countis E50 for a new project, ask your supplier to confirm current availability and whether a newer equivalent is recommended.
Installation Tips for Socomec Countis E50 in UAE Conditions
Good data starts with correct installation. These steps apply to most three-phase CT installations.
- Size the CTs correctly. Choose a primary rating just above the feeder’s normal maximum current, with a 5 A secondary for the 4850 3010 reference.
- Match CT direction and phase. Reversed or swapped CTs cause wrong power readings. The Socomec Countis E50 can detect connection errors, which helps catch this at commissioning.
- Keep CT secondaries safe. Never open-circuit a live CT secondary. Use shorting terminals.
- Enter the CT ratio and pulse settings. Record them on the commissioning sheet.
- Verify against a known load. Compare the meter’s kWh and kW with a clamp meter reading or a known load.
Heat and enclosure planning
During the summer in the UAE, the switchroom and panels get very hot. Check the datasheet for the highest temperature that the device can work at, and leave space around the meter for air flow. Also, remember the 92 × 92 mm cutout and the depth of about 80 mm when planning to install it on a door.
Document for audits
Keep a record of meter reference, serial number, CT ratio, location and commissioning date. If your site pursues green building or energy-audit goals, this record saves time later.
Conclusion
The Socomec Countis E50 is a practical, CT-connected energy meter for feeder-level monitoring on Sites for businesses, factories, and data centers. There is a pulse output that makes integration easy. If you need Modbus data, the E53 is a better choice. Dubai wants to save 30% by 2030 and 50% by 2050. If a business in the UAE wants to manage its energy use instead of just paying for it, accurate sub-metering is a good place to start.
If you are planning a metering or power-monitoring project, explore our power and energy services and metering and monitoring solutions. You can also learn about the dcpsme.com team, read more energy management articles, or contact dcpsme.com for Socomec Countis E50 advice tailored to your site.